Monte Carlo evaluation of scatter mitigation strategies in cone‐beam CT

Lazos et al., 2010

View PDF
Document ID
4551420081070679338
Author
Lazos D
Williamson J
Publication year
Publication venue
Medical physics

External Links

Snippet

Purpose: To investigate the efficacy of two widely used scatter mitigation methods: antiscatter grids (ASGs) and beam modulating with bowtie filters (BTFs), in combination with subtractive scatter correction or zeroth order normalization phantom calibration, for …
Continue reading at pmc.ncbi.nlm.nih.gov (PDF) (other versions)

Classifications

    • AHUMAN NECESSITIES
    • A61MEDICAL OR VETERINARY SCIENCE; HYGIENE
    • A61NELECTROTHERAPY; MAGNETOTHERAPY; RADIATION THERAPY; ULTRASOUND THERAPY
    • A61N5/00Radiation therapy
    • A61N5/10X-ray therapy; Gamma-ray therapy; Particle-irradiation therapy
    • A61N5/103Treatment planning systems
    • A61N5/1031Treatment planning systems using a specific method of dose optimization
    • AHUMAN NECESSITIES
    • A61MEDICAL OR VETERINARY SCIENCE; HYGIENE
    • A61BDIAGNOSIS; SURGERY; IDENTIFICATION
    • A61B6/00Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
    • A61B6/02Devices for diagnosis sequentially in different planes; Stereoscopic radiation diagnosis
    • A61B6/03Computerised tomographs
    • A61B6/032Transmission computed tomography [CT]
    • AHUMAN NECESSITIES
    • A61MEDICAL OR VETERINARY SCIENCE; HYGIENE
    • A61BDIAGNOSIS; SURGERY; IDENTIFICATION
    • A61B6/00Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
    • A61B6/48Diagnostic techniques
    • A61B6/482Diagnostic techniques involving multiple energy imaging
    • AHUMAN NECESSITIES
    • A61MEDICAL OR VETERINARY SCIENCE; HYGIENE
    • A61BDIAGNOSIS; SURGERY; IDENTIFICATION
    • A61B6/00Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
    • A61B6/58Testing, adjusting or calibrating devices for radiation diagnosis
    • A61B6/582Calibration
    • AHUMAN NECESSITIES
    • A61MEDICAL OR VETERINARY SCIENCE; HYGIENE
    • A61NELECTROTHERAPY; MAGNETOTHERAPY; RADIATION THERAPY; ULTRASOUND THERAPY
    • A61N5/00Radiation therapy
    • A61N5/10X-ray therapy; Gamma-ray therapy; Particle-irradiation therapy
    • A61N2005/1092Details
    • AHUMAN NECESSITIES
    • A61MEDICAL OR VETERINARY SCIENCE; HYGIENE
    • A61BDIAGNOSIS; SURGERY; IDENTIFICATION
    • A61B6/00Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
    • A61B6/40Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment with arrangements for generating radiation specially adapted for radiation diagnosis
    • A61B6/4064Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment with arrangements for generating radiation specially adapted for radiation diagnosis adapted for producing a particular type of beam
    • AHUMAN NECESSITIES
    • A61MEDICAL OR VETERINARY SCIENCE; HYGIENE
    • A61BDIAGNOSIS; SURGERY; IDENTIFICATION
    • A61B6/00Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
    • A61B6/42Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment with arrangements for detecting radiation specially adapted for radiation diagnosis
    • A61B6/4291Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment with arrangements for detecting radiation specially adapted for radiation diagnosis the detector being combined with a grid or grating
    • AHUMAN NECESSITIES
    • A61MEDICAL OR VETERINARY SCIENCE; HYGIENE
    • A61BDIAGNOSIS; SURGERY; IDENTIFICATION
    • A61B6/00Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
    • A61B6/42Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment with arrangements for detecting radiation specially adapted for radiation diagnosis
    • A61B6/4208Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment with arrangements for detecting radiation specially adapted for radiation diagnosis characterised by using a particular type of detector
    • A61B6/4241Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment with arrangements for detecting radiation specially adapted for radiation diagnosis characterised by using a particular type of detector using energy resolving detectors, e.g. photon counting
    • GPHYSICS
    • G21NUCLEAR PHYSICS; NUCLEAR ENGINEERING
    • G21KTECHNIQUES FOR HANDLING PARTICLES OR IONISING RADIATION NOT OTHERWISE PROVIDED FOR; IRRADIATION DEVICES; GAMMA RAY OR X-RAY MICROSCOPES
    • G21K1/00Arrangements for handling particles or ionizing radiation, e.g. focusing or moderating
    • G21K1/02Arrangements for handling particles or ionizing radiation, e.g. focusing or moderating using diaphragms, collimators

Similar Documents

Publication Publication Date Title
Jarry et al. Characterization of scattered radiation in kV CBCT images using Monte Carlo simulations
Kwan et al. Evaluation of x‐ray scatter properties in a dedicated cone‐beam breast CT scanner
Mail et al. The influence of bowtie filtration on cone‐beam CT image quality
Zhu et al. Scatter correction for cone‐beam CT in radiation therapy
Siewerdsen et al. Cone‐beam computed tomography with a flat‐panel imager: magnitude and effects of x‐ray scatter
Sisniega et al. Monte Carlo study of the effects of system geometry and antiscatter grids on cone‐beam CT scatter distributions
Niu et al. Shading correction for on‐board cone‐beam CT in radiation therapy using planning MDCT images
Graham et al. Compensators for dose and scatter management in cone‐beam computed tomography
Szczykutowicz et al. Design of a digital beam attenuation system for computed tomography: Part I. System design and simulation framework
Zhao et al. Noise, sampling, and the number of projections in cone‐beam CT with a flat‐panel detector
Mainprize et al. Resolution at oblique incidence angles of a flat panel imager for breast tomosynthesis
Wu et al. Metal artifact correction for x‐ray computed tomography using kV and selective MV imaging
Bootsma et al. The effects of compensator and imaging geometry on the distribution of x‐ray scatter in CBCT
Ouyang et al. A moving blocker system for cone‐beam computed tomography scatter correction
US20120002781A1 (en) Optimized aperture selection imaging computed tomography system and method
Ren et al. Feasibility study of as ynchronized‐mo ving‐g rid (SMOG) system to improve image quality in cone‐beam computed tomography (CBCT)
Alexeev et al. Two‐dimensional antiscatter grid: A novel scatter rejection device for Cone‐beam computed tomography
Lazos et al. Monte Carlo evaluation of scatter mitigation strategies in cone‐beam CT
Paudel et al. Evaluation of normalized metal artifact reduction (NMAR) in kVCT using MVCT prior images for radiotherapy treatment planning
Hupfer et al. Dosimetry concepts for scanner quality assurance and tissue dose assessment in micro‐CT
Mail et al. An empirical method for lag correction in cone‐beam CT
Li et al. Implementation of dual‐energy technique for virtual monochromatic and linearly mixed CBCTs
Mettivier et al. Cone‐beam breast computed tomography with a displaced flat panel detector array
Maltz et al. Focused beam‐stop array for the measurement of scatter in megavoltage portal and cone beam CT imaging
Chen et al. Optimization of the geometry and speed of a moving blocker system for cone‐beam computed tomography scatter correction