Pallotta et al., 2018 - Google Patents
ADAM: A breathing phantom for lung SBRT quality assurancePallotta et al., 2018
- Document ID
- 6301916563461532448
- Author
- Pallotta S
- Calusi S
- Foggi L
- Lisci R
- Masi L
- Marrazzo L
- Talamonti C
- Livi L
- Simontacchi G
- Publication year
- Publication venue
- Physica Medica
External Links
Snippet
Purpose Radiotherapy treatment of moving lesions is a challenging task in which different strategies can be used to adequately treat the tumor while sparing the surrounding tissue. The complexity of these strategies requires accurate and appropriate quality assurance …
- 210000004072 Lung 0 title abstract description 59
Classifications
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61N—ELECTROTHERAPY; MAGNETOTHERAPY; RADIATION THERAPY; ULTRASOUND THERAPY
- A61N5/00—Radiation therapy
- A61N5/10—X-ray therapy; Gamma-ray therapy; Particle-irradiation therapy
- A61N5/1048—Monitoring, verifying, controlling systems and methods
- A61N5/1064—Monitoring, verifying, controlling systems and methods for adjusting radiation treatment in response to monitoring
- A61N5/1065—Beam adjustment
- A61N5/1067—Beam adjustment in real time, i.e. during treatment
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61N—ELECTROTHERAPY; MAGNETOTHERAPY; RADIATION THERAPY; ULTRASOUND THERAPY
- A61N5/00—Radiation therapy
- A61N5/10—X-ray therapy; Gamma-ray therapy; Particle-irradiation therapy
- A61N5/1048—Monitoring, verifying, controlling systems and methods
- A61N5/1075—Monitoring, verifying, controlling systems and methods for testing, calibrating, or quality assurance of the radiation treatment apparatus
- A61N2005/1076—Monitoring, verifying, controlling systems and methods for testing, calibrating, or quality assurance of the radiation treatment apparatus using a dummy object placed in the radiation field, e.g. phantom
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61N—ELECTROTHERAPY; MAGNETOTHERAPY; RADIATION THERAPY; ULTRASOUND THERAPY
- A61N5/00—Radiation therapy
- A61N5/10—X-ray therapy; Gamma-ray therapy; Particle-irradiation therapy
- A61N5/1048—Monitoring, verifying, controlling systems and methods
- A61N5/1049—Monitoring, verifying, controlling systems and methods for verifying the position of the patient with respect to the radiation beam
- A61N2005/1061—Monitoring, verifying, controlling systems and methods for verifying the position of the patient with respect to the radiation beam using an x-ray imaging system having a separate imaging source
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B6/00—Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
- A61B6/58—Testing, adjusting or calibrating devices for radiation diagnosis
- A61B6/582—Calibration
- A61B6/583—Calibration using calibration phantoms
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B5/00—Detecting, measuring or recording for diagnostic purposes; Identification of persons
- A61B5/103—Detecting, measuring or recording devices for testing the shape, pattern, colour, size or movement of the body or parts thereof, for diagnostic purposes
- A61B5/11—Measuring movement of the entire body or parts thereof, e.g. head or hand tremor, mobility of a limb
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B6/00—Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
- A61B6/04—Positioning of patients; Tiltable beds or the like
- A61B6/0492—Positioning of patients; Tiltable beds or the like using markers or indicia for aiding patient positioning
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B6/00—Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
- A61B6/04—Positioning of patients; Tiltable beds or the like
- A61B6/0407—Tables or beds
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B6/00—Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
- A61B6/54—Control of devices for radiation diagnosis
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B6/00—Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
- A61B6/48—Diagnostic techniques
Similar Documents
| Publication | Publication Date | Title |
|---|---|---|
| Pallotta et al. | ADAM: A breathing phantom for lung SBRT quality assurance | |
| Bertholet et al. | Real-time intrafraction motion monitoring in external beam radiotherapy | |
| Schnarr et al. | Feasibility of real‐time motion management with helical tomotherapy | |
| US7667191B2 (en) | Deformable phantom apparatus | |
| Hoogeman et al. | Clinical accuracy of the respiratory tumor tracking system of the cyberknife: assessment by analysis of log files | |
| Ford et al. | Evaluation of respiratory movement during gated radiotherapy using film and electronic portal imaging | |
| CN103313756B (en) | Irradiated phantom | |
| Steidl et al. | A breathing thorax phantom with independently programmable 6D tumour motion for dosimetric measurements in radiation therapy | |
| Perrin et al. | An anthropomorphic breathing phantom of the thorax for testing new motion mitigation techniques for pencil beam scanning proton therapy | |
| US20170169734A1 (en) | A dynamic phantom | |
| Ehrbar et al. | ELPHA: Dynamically deformable liver phantom for real‐time motion‐adaptive radiotherapy treatments | |
| Aznar et al. | Irregular breathing during 4DCT scanning of lung cancer patients: is the midventilation approach robust? | |
| Cheung et al. | An externally and internally deformable, programmable lung motion phantom | |
| Malinowski et al. | Development of the 4D Phantom for patient-specific end-to-end radiation therapy QA | |
| Fattori et al. | Commissioning and quality assurance of a novel solution for respiratory-gated PBS proton therapy based on optical tracking of surface markers | |
| Sumida et al. | Evaluation of tracking accuracy of the CyberKnife system using a webcam and printed calibrated grid | |
| Pallotta et al. | ADAM phantom to test 4D medical imaging and dose delivery devices | |
| Poels et al. | A complementary dual-modality verification for tumor tracking on a gimbaled linac system | |
| Gholampourkashi et al. | Development of a deformable phantom for experimental verification of 4D Monte Carlo simulations in a deforming anatomy | |
| Tajik et al. | Advances in anthropomorphic thorax phantoms for radiotherapy: a review | |
| US10898157B2 (en) | Deformable lung model apparatus | |
| Ranjbar et al. | A novel deformable lung phantom with programably variable external and internal correlation | |
| Nakayama et al. | Film measurement and analytical approach for assessing treatment accuracy and latency in a magnetic resonance‐guided radiotherapy system | |
| Erdoğan et al. | Patient-specific tumor and respiratory monitoring phantom design for quality controls of stereotactic ablative body radiotherapy in lung cancer cases | |
| Barbés et al. | Development and clinical evaluation of a simple optical method to detect and measure patient external motion |