[go: up one dir, main page]

Mason et al., 1975 - Google Patents

Reactivity of blood with biomaterials in vitro: evaluation of some in vitro test systems for estimation of the blood compatibility of biomaterials

Mason et al., 1975

Document ID
6507484089100423139
Author
Mason R
Shinoda B
Publication year
Publication venue
Biomaterials, Medical Devices, and Artificial Organs

External Links

Snippet

Several different in vitro tests designed to estimate the degree of compatibility of blood with biomaterials have been examined to determine possible effects of donor or donor-material interaction. Statistical evaluation of data was performed, and adequate data were collected …
Continue reading at www.tandfonline.com (other versions)

Classifications

    • GPHYSICS
    • G01MEASURING; TESTING
    • G01NINVESTIGATING OR ANALYSING MATERIALS BY DETERMINING THEIR CHEMICAL OR PHYSICAL PROPERTIES
    • G01N33/00Investigating or analysing materials by specific methods not covered by the preceding groups
    • G01N33/48Investigating or analysing materials by specific methods not covered by the preceding groups biological material, e.g. blood, urine; Haemocytometers
    • G01N33/483Physical analysis of biological material
    • G01N33/487Physical analysis of biological material of liquid biological material
    • G01N33/49Blood
    • G01N33/4905Determining clotting time of blood
    • GPHYSICS
    • G01MEASURING; TESTING
    • G01NINVESTIGATING OR ANALYSING MATERIALS BY DETERMINING THEIR CHEMICAL OR PHYSICAL PROPERTIES
    • G01N33/00Investigating or analysing materials by specific methods not covered by the preceding groups
    • G01N33/48Investigating or analysing materials by specific methods not covered by the preceding groups biological material, e.g. blood, urine; Haemocytometers
    • G01N33/50Chemical analysis of biological material, e.g. blood, urine; Testing involving biospecific ligand binding methods; Immunological testing
    • G01N33/80Chemical analysis of biological material, e.g. blood, urine; Testing involving biospecific ligand binding methods; Immunological testing involving blood groups or blood types or red blood cells
    • GPHYSICS
    • G01MEASURING; TESTING
    • G01NINVESTIGATING OR ANALYSING MATERIALS BY DETERMINING THEIR CHEMICAL OR PHYSICAL PROPERTIES
    • G01N33/00Investigating or analysing materials by specific methods not covered by the preceding groups
    • G01N33/48Investigating or analysing materials by specific methods not covered by the preceding groups biological material, e.g. blood, urine; Haemocytometers
    • G01N33/50Chemical analysis of biological material, e.g. blood, urine; Testing involving biospecific ligand binding methods; Immunological testing
    • G01N33/86Chemical analysis of biological material, e.g. blood, urine; Testing involving biospecific ligand binding methods; Immunological testing involving blood coagulating time or factors, or their receptors
    • GPHYSICS
    • G01MEASURING; TESTING
    • G01NINVESTIGATING OR ANALYSING MATERIALS BY DETERMINING THEIR CHEMICAL OR PHYSICAL PROPERTIES
    • G01N33/00Investigating or analysing materials by specific methods not covered by the preceding groups
    • G01N33/48Investigating or analysing materials by specific methods not covered by the preceding groups biological material, e.g. blood, urine; Haemocytometers
    • G01N33/50Chemical analysis of biological material, e.g. blood, urine; Testing involving biospecific ligand binding methods; Immunological testing
    • G01N33/5005Chemical analysis of biological material, e.g. blood, urine; Testing involving biospecific ligand binding methods; Immunological testing involving human or animal cells
    • GPHYSICS
    • G01MEASURING; TESTING
    • G01NINVESTIGATING OR ANALYSING MATERIALS BY DETERMINING THEIR CHEMICAL OR PHYSICAL PROPERTIES
    • G01N33/00Investigating or analysing materials by specific methods not covered by the preceding groups
    • G01N33/48Investigating or analysing materials by specific methods not covered by the preceding groups biological material, e.g. blood, urine; Haemocytometers
    • G01N33/50Chemical analysis of biological material, e.g. blood, urine; Testing involving biospecific ligand binding methods; Immunological testing
    • G01N33/53Immunoassay; Biospecific binding assay
    • AHUMAN NECESSITIES
    • A61MEDICAL OR VETERINARY SCIENCE; HYGIENE
    • A61MDEVICES FOR INTRODUCING MEDIA INTO, OR ONTO, THE BODY; DEVICES FOR TRANSDUCING BODY MEDIA OR FOR TAKING MEDIA FROM THE BODY; DEVICES FOR PRODUCING OR ENDING SLEEP OR STUPOR
    • A61M1/00Suction or pumping devices for medical purposes; Devices for carrying-off, for treatment of, or for carrying-over, body-liquids; Drainage systems
    • A61M1/36Other treatment of blood in a by-pass of the natural circulatory system, e.g. temperature adaptation, irradiation; Extra-corporeal blood circuits

Similar Documents

Publication Publication Date Title
Boyd et al. Permeability of lung capillaries to macromolecules in foetal and new‐born lambs and sheep
Ruggeri et al. Immunoradiometric assay of factor VIII related antigen, with observations in 32 patients with von Willebrand's disease
Olson et al. Evaluation of Ristocetin–Willebrand Factor Assay and Ristocetin-induced Platelet Aggregation
O'brien et al. Shear stress activation of platelet glycoprotein IIb/IIIa plus von Willebrand factor causes aggregation: filter blockage and the long bleeding time in von Willebrand's disease
US5089422A (en) Vitro bleeding time determination
Caekebeke‐Peerlinck et al. Bleeding time, blood groups and von Willebrand factor
Horowitz et al. Change in platelet factor 3 as a means of demonstrating immune reactions involving platelets: its use as a test for quinidine‐induced thrombocytopenia
Chaplin et al. Quantitation of red blood cell‐bound C3d in normal subjects and random hospitalized patients
Evans et al. Assay of ristocetin co‐factor using fixed platelets and a platelet counting technique
Kim et al. Effect of phthalate plasticizer on blood compatibility of polyvinyl chloride
Alving et al. In vitro studies of heparin-associated thrombocytopenia
Lindsay Platelets, foreign surfaces, and heparin
Parzer et al. Plasma protein adsorption to hemodialysis membranes: studies in an in vitro model
Mason et al. Reactivity of blood with biomaterials in vitro: evaluation of some in vitro test systems for estimation of the blood compatibility of biomaterials
Bowry et al. Utilization of the platelet release reaction in the blood compatibility assessment of polymers
Bowry et al. A modification of the Wu and Hoak method for the determination of platelet aggregates and platelet adhesion
Ur Detection of clot retraction through changes of the electrical impedance of blood during coagulation
Green et al. Urinary loss of clotting factors due to hereditary membranous glomerulopathy
Bruck Evaluation of blood compatibility of polymeric implants
Limber et al. Studies of the proteins elutable from certain artificial surfaces exposed to human plasma
Jung et al. Haemocompatibility of Endovascular Coronary Stents: Wiktor GX©. Hämokompatibilität von Koronarstents: Wiktor GX©
Zucker et al. Experimental interactions of components of hemodialysis units with human blood
Abe et al. Rheumatoid factor-like substance and antistreptolysin O antibody in leprosy serum
Perkins et al. Low molecular weight dextran in open heart surgery: Effect on coagulation factors and on red cell antibody activity
Rampling et al. Fibrinogen, fibrinogen degradation products and erythrocyte flexibility