Sarasola et al., 2011 - Google Patents
A novel front-end chip for a human PET scanner based on monolithic detector blocksSarasola et al., 2011
View PDF- Document ID
- 8480548425159168334
- Author
- Sarasola I
- Mendes P
- Cuerdo R
- De Acilu P
- Navarrete J
- Cela J
- Oller J
- Romero L
- Pérez J
- Publication year
- Publication venue
- Journal of Instrumentation
External Links
Snippet
We are developing a positron emission tomography (PET) scanner based on avalanche photodiodes (APD), monolithic LYSO: Ce scintillator crystals and a dedicated readout chip. All these components allow operation inside a magnetic resonance imaging (MRI) scanner …
- 238000002600 positron emission tomography 0 abstract description 39
Classifications
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01T—MEASUREMENT OF NUCLEAR OR X-RADIATION
- G01T1/00—Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
- G01T1/16—Measuring radiation intensity
- G01T1/161—Application in the field of nuclear medicine, e.g. in vivo counting
- G01T1/164—Scintigraphy
- G01T1/1641—Static instruments for imaging the distribution of radioactivity in one or two dimensions using one or several scintillating elements; Radio-isotope cameras
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01T—MEASUREMENT OF NUCLEAR OR X-RADIATION
- G01T1/00—Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
- G01T1/29—Measurement performed on radiation beams, e.g. position or section of the beam; Measurement of spatial distribution of radiation
- G01T1/2914—Measurement of spatial distribution of radiation
- G01T1/2985—In depth localisation, e.g. using positron emitters; Tomographic imaging (longitudinal and transverse section imaging; apparatus for radiation diagnosis sequentially in different planes, steroscopic radiation diagnosis)
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01T—MEASUREMENT OF NUCLEAR OR X-RADIATION
- G01T1/00—Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
- G01T1/16—Measuring radiation intensity
- G01T1/20—Measuring radiation intensity with scintillation detectors
- G01T1/2018—Scintillation-photodiode combination
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01T—MEASUREMENT OF NUCLEAR OR X-RADIATION
- G01T1/00—Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
- G01T1/16—Measuring radiation intensity
- G01T1/20—Measuring radiation intensity with scintillation detectors
- G01T1/2008—Measuring radiation intensity with scintillation detectors using a combination of different types of scintillation detectors, e.g. phoswich
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01T—MEASUREMENT OF NUCLEAR OR X-RADIATION
- G01T1/00—Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
- G01T1/16—Measuring radiation intensity
- G01T1/24—Measuring radiation intensity with semiconductor detectors
- G01T1/241—Electrode arrangements, e.g. continuous or parallel strips or the like
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01T—MEASUREMENT OF NUCLEAR OR X-RADIATION
- G01T1/00—Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
- G01T1/16—Measuring radiation intensity
- G01T1/24—Measuring radiation intensity with semiconductor detectors
- G01T1/247—Detector read-out circuitry
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01T—MEASUREMENT OF NUCLEAR OR X-RADIATION
- G01T1/00—Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
- G01T1/16—Measuring radiation intensity
- G01T1/20—Measuring radiation intensity with scintillation detectors
- G01T1/202—Measuring radiation intensity with scintillation detectors the detector being a crystal
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01T—MEASUREMENT OF NUCLEAR OR X-RADIATION
- G01T1/00—Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
- G01T1/16—Measuring radiation intensity
- G01T1/17—Circuit arrangements not adapted to a particular type of detector
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01T—MEASUREMENT OF NUCLEAR OR X-RADIATION
- G01T1/00—Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
- G01T1/02—Dosimeters
- G01T1/026—Semiconductor dose-rate meters
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01R—MEASURING ELECTRIC VARIABLES; MEASURING MAGNETIC VARIABLES
- G01R33/00—Arrangements or instruments for measuring magnetic variables
- G01R33/20—Arrangements or instruments for measuring magnetic variables involving magnetic resonance
- G01R33/44—Arrangements or instruments for measuring magnetic variables involving magnetic resonance using nuclear magnetic resonance [NMR]
- G01R33/48—NMR imaging systems
- G01R33/4808—Multimodal MR, e.g. MR combined with positron emission tomography [PET], MR combined with ultrasound or MR combined with computed tomography [CT]
- G01R33/481—MR combined with positron emission tomography [PET] or single photon emission computed tomography [SPECT]
Similar Documents
| Publication | Publication Date | Title |
|---|---|---|
| Schug et al. | Initial measurements with the PETsys TOFPET2 ASIC evaluation kit and a characterization of the ASIC TDC | |
| González et al. | The MINDView brain PET detector, feasibility study based on SiPM arrays | |
| US9176240B2 (en) | Apparatus and method for channel count reduction in solid-state-based positron emission tomography | |
| US8884240B1 (en) | Position sensitive solid-state photomultipliers, systems and methods | |
| Kwon et al. | Signal encoding method for a time-of-flight PET detector using a silicon photomultiplier array | |
| Venialgo et al. | Toward a full-flexible and fast-prototyping TOF-PET block detector based on TDC-on-FPGA | |
| Kato et al. | A novel gamma-ray detector with submillimeter resolutions using a monolithic MPPC array with pixelized Ce: LYSO and Ce: GGAG crystals | |
| Li et al. | Study of PET detector performance with varying SiPM parameters and readout schemes | |
| Huber et al. | Characterization of a 64 channel PET detector using photodiodes for crystal identification | |
| Gu et al. | A DOI detector with crystal scatter identification capability for high sensitivity and high spatial resolution PET imaging | |
| Nakamori et al. | Development of a gamma-ray imager using a large area monolithic 4× 4 MPPC array for a future PET scanner | |
| Park et al. | Digital coincidence processing for the RatCAP conscious rat brain PET scanner | |
| Pourashraf et al. | Investigation of electronic signal processing chains for a prototype TOF-PET system with 100-ps coincidence time resolution | |
| Wang et al. | Energy calibration using scintillator background radiation for high-resolution PET detectors | |
| Lee et al. | Advancements in positron emission tomography detectors: from silicon photomultiplier technology to artificial intelligence applications | |
| Grodzicka-Kobylka et al. | Silicon photomultipliers in scintillation detectors used for gamma ray energies up to 6.1 MeV | |
| Lemaire et al. | Dark count resilient time estimators for time-of-flight PET | |
| Zhao et al. | Development of a modular high-sensitivity high-uniformity gamma camera for radiation monitoring applications | |
| Sacco | Development of highly integrated PET/MR detector modules | |
| Lemaire et al. | Embedded time of arrival estimation for digital silicon photomultipliers with in-pixel TDCs | |
| González et al. | Performance study of a wide-area SiPM array, ASICs controlled | |
| Aguilar et al. | Timing results using an FPGA-based TDC with large arrays of 144 SiPMs | |
| Sarasola et al. | A novel front-end chip for a human PET scanner based on monolithic detector blocks | |
| Samson et al. | A fully automated and scalable timing probe-based method for time alignment of the LabPET II scanners | |
| David et al. | Imaging performance of silicon photomultipliers coupled to BGO and CsI: Na arrays |