Korkmaz et al., 1999 - Google Patents
Segmented detector for recoil neutrons in the p (γ, n) π+ reactionKorkmaz et al., 1999
- Document ID
- 8654758793667295959
- Author
- Korkmaz E
- O'Rielly G
- Hutcheon D
- Feldman G
- Jordan D
- Kolb N
- Pywell R
- Retzlaff G
- Sawatzky B
- Skopik D
- Vogt J
- Cairns E
- Giesen U
- Holm L
- Opper A
- Rozon F
- Soukup J
- Publication year
- Publication venue
- Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
External Links
Snippet
A segmented neutron detector has been constructed and used for recoil neutron (6–13MeV) measurements of the reaction γp→ nπ+ very close to threshold. BC-505 liquid scintillator was used to allow pulse shape discrimination between neutrons and photons. A …
- 238000006243 chemical reaction 0 title abstract description 37
Classifications
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01T—MEASUREMENT OF NUCLEAR OR X-RADIATION
- G01T1/00—Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
- G01T1/02—Dosimeters
- G01T1/026—Semiconductor dose-rate meters
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01T—MEASUREMENT OF NUCLEAR OR X-RADIATION
- G01T1/00—Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
- G01T1/16—Measuring radiation intensity
- G01T1/17—Circuit arrangements not adapted to a particular type of detector
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01T—MEASUREMENT OF NUCLEAR OR X-RADIATION
- G01T1/00—Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
- G01T1/02—Dosimeters
- G01T1/10—Luminescent dosimeters
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01T—MEASUREMENT OF NUCLEAR OR X-RADIATION
- G01T1/00—Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
- G01T1/29—Measurement performed on radiation beams, e.g. position or section of the beam; Measurement of spatial distribution of radiation
- G01T1/2914—Measurement of spatial distribution of radiation
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01T—MEASUREMENT OF NUCLEAR OR X-RADIATION
- G01T1/00—Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
- G01T1/36—Measuring spectral distribution of X-rays or of nuclear radiation spectrometry
Similar Documents
| Publication | Publication Date | Title |
|---|---|---|
| Hurtado et al. | GEANT4 code for simulation of a germanium gamma-ray detector and its application to efficiency calibration | |
| Howell et al. | Toward a resolution of the neutron-neutron scattering-length issue | |
| Lepy et al. | Intercomparison of efficiency transfer software for gamma-ray spectrometry | |
| Nolte et al. | High-energy neutron reference fields for the calibration of detectors used in neutron spectrometry | |
| Wiegel et al. | Intercomparison of radiation protection devices in a high-energy stray neutron field, Part II: Bonner sphere spectrometry | |
| Gasparro et al. | Monte Carlo modelling of germanium crystals that are tilted and have rounded front edges | |
| Becchetti et al. | Deuterated-xylene (xylene-d10; EJ301D): A new, improved deuterated liquid scintillator for neutron energy measurements without time-of-flight | |
| Kelleter et al. | A mathematical expression for depth‐light curves of therapeutic proton beams in a quenching scintillator | |
| Morera-Gómez et al. | Validation of an efficiency calibration procedure for a coaxial n-type and a well-type HPGe detector used for the measurement of environmental radioactivity | |
| Croft et al. | A review of the prompt neutron nu-bar value for 252Cf spontaneous fission | |
| Sima | Accurate calculation of total efficiency of Ge well-type detectors suitable for efficiency calibration using common standard sources | |
| Callaghan et al. | Measurement of proton light yield of water-based liquid scintillator | |
| Stevanato et al. | Light output of EJ228 scintillation neutron detectors | |
| Korkmaz et al. | Segmented detector for recoil neutrons in the p (γ, n) π+ reaction | |
| Bagherzadeh-Atashchi et al. | Neutron spectroscopy with TENIS using an artificial neural network | |
| Pywell et al. | Light output response of BC-505 liquid scintillator | |
| Nutter et al. | Measurement of delayed fluorescence in plastic scintillator from 1 to 10 μs | |
| Vidmar et al. | Calculation of “LS-curves” for coincidence summing corrections in gamma ray spectrometry | |
| Baek et al. | Investigation of γ-multiplicity spectra and neutron capture cross-sections of 232Th in the energy region 21.5–215 eV | |
| Blain et al. | A method to measure prompt fission neutron spectrum using gamma multiplicity tagging | |
| Wagner et al. | Detection of relativistic neutrons by BaF2 scintillators | |
| Waker | A preliminary study of the performance of a novel design of multi-element tissue equivalent proportional counter for neutron monitoring | |
| Jesus et al. | Influence of target thickness on resonant elastic scattering of protons by 19F | |
| Devlin et al. | Prompt Fission Neutron Spectra for Neutron-Induced Fission of 239Pu and 235U | |
| Kampmann et al. | A semi-analytical energy response model for low-energy events in JUNO |