The use of digitally reconstructed radiographs for three-dimensional treatment planning and CT-simulationGalvin et al., 1995
View PDF- Document ID
- 8650073467835201077
- Author
- Galvin J
- Sims C
- Dominiak G
- Cooper J
- Publication year
- Publication venue
- International Journal of Radiation Oncology* Biology* Physics
External Links
Snippet
Purpose: Recent interest in computed tomography-simulation (CT-simulation) suggests the possibility of a shift to digital images for field verification. This article examines the quality of Digitally Reconstructed Radiographs (DRRs) to determine if they can reasonably be …
- 238000004088 simulation 0 title abstract description 7
Classifications
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B6/00—Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
- A61B6/02—Devices for diagnosis sequentially in different planes; Stereoscopic radiation diagnosis
- A61B6/03—Computerised tomographs
- A61B6/032—Transmission computed tomography [CT]
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B6/00—Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
- A61B6/40—Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment with arrangements for generating radiation specially adapted for radiation diagnosis
- A61B6/4064—Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment with arrangements for generating radiation specially adapted for radiation diagnosis adapted for producing a particular type of beam
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B6/00—Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
- A61B6/48—Diagnostic techniques
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B6/00—Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
- A61B6/50—Clinical applications
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B6/00—Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
- A61B6/58—Testing, adjusting or calibrating devices for radiation diagnosis
- A61B6/582—Calibration
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B5/00—Detecting, measuring or recording for diagnostic purposes; Identification of persons
- A61B5/72—Signal processing specially adapted for physiological signals or for diagnostic purposes
- A61B5/7271—Specific aspects of physiological measurement analysis
- A61B5/7285—Specific aspects of physiological measurement analysis for synchronising or triggering a physiological measurement or image acquisition with a physiological event or waveform, e.g. an ECG signal
-
- G—PHYSICS
- G06—COMPUTING; CALCULATING; COUNTING
- G06T—IMAGE DATA PROCESSING OR GENERATION, IN GENERAL
- G06T11/00—2D [Two Dimensional] image generation
- G06T11/003—Reconstruction from projections, e.g. tomography
- G06T11/005—Specific pre-processing for tomographic reconstruction, e.g. calibration, source positioning, rebinning, scatter correction, retrospective gating
Similar Documents
| Publication | Publication Date | Title |
|---|---|---|
| Galvin et al. | The use of digitally reconstructed radiographs for three-dimensional treatment planning and CT-simulation | |
| Pan et al. | 4D‐CT imaging of a volume influenced by respiratory motion on multi‐slice CT | |
| US7177453B2 (en) | Method and apparatus for partitioning a volume | |
| US8483363B2 (en) | Movable wedge for improved image quality in 3D X-ray imaging | |
| Hsieh | Adaptive streak artifact reduction in computed tomography resulting from excessive x‐ray photon noise | |
| US6735273B2 (en) | X-ray computed tomography apparatus and multi-spectra correction using a radiation pre-filter | |
| US6600801B2 (en) | Method for correcting for beam hardening in a CT image | |
| Kennedy et al. | Super-resolution in PET imaging | |
| US8879817B2 (en) | Scan plan field of view adjustor, determiner, and/or quality assessor | |
| JP4965433B2 (en) | Cone beam CT apparatus using truncated projection and pre-acquired 3D CT image | |
| US6496560B1 (en) | Motion correction for perfusion measurements | |
| McCollough et al. | The technical design and performance of ultrafast computed tomography | |
| US20090135994A1 (en) | System And Method For Creating Mixed Image From Dual-Energy CT Data | |
| US6246742B1 (en) | Local CT image reconstruction with limited x-ray exposure | |
| Flohr et al. | Image reconstruction and performance evaluation for ECG‐gated spiral scanning with a 16‐slice CT system | |
| US20060291711A1 (en) | Imaging chain for digital tomosynthesis on a flat panel detector | |
| US20040114727A1 (en) | Method and apparatus for imaging a region of dynamic tissue | |
| US20080267455A1 (en) | Method for Movement Compensation of Image Data | |
| JP2002345808A (en) | Method and system for process of scouting ct images | |
| US20090225934A1 (en) | Keyhole computed tomography | |
| GB2250164A (en) | Producing medical images corrected for patient movement | |
| IL158197A (en) | Methods and apparatus for truncation compensation | |
| JP2002017716A (en) | Method and device for multi-slice ct scanning for region of interest | |
| CN109381214B (en) | Computed tomography recording with different energy threshold sets | |
| US20070147579A1 (en) | Method and system for radiographic imaging with organ-based radiation profile prescription |