Gil et al., 2012 - Google Patents
Optimization of energy consumption in HPC centers: Energy Efficiency Project of Castile and Leon Supercomputing Center-FCSCLGil et al., 2012
View PDF- Document ID
- 9250108337778675108
- Author
- Gil C
- Ruiz-Falcó A
- Martínez J
- et al.
- Publication year
- Publication venue
- RE&PQJ
External Links
Snippet
Supercomputers are very intensive in energy consumption. Large clusters are composed of hundreds or thousands of processors working in parallel, as is easily seen, the processors are the system component that consumes the most. An indicative figure is that a standard …
- 238000005265 energy consumption 0 title abstract description 7
Classifications
-
- H—ELECTRICITY
- H05—ELECTRIC TECHNIQUES NOT OTHERWISE PROVIDED FOR
- H05K—PRINTED CIRCUITS; CASINGS OR CONSTRUCTIONAL DETAILS OF ELECTRIC APPARATUS; MANUFACTURE OF ASSEMBLAGES OF ELECTRICAL COMPONENTS
- H05K7/00—Constructional details common to different types of electric apparatus
- H05K7/20—Modifications to facilitate cooling, ventilating, or heating
- H05K7/20709—Modifications to facilitate cooling, ventilating, or heating for server racks or cabinets; for data centers, e.g. 19-inch computer racks
- H05K7/20718—Forced ventilation of a gaseous coolant
- H05K7/20745—Forced ventilation of a gaseous coolant within rooms for removing heat from cabinets, e.g. by air conditioning device
-
- G—PHYSICS
- G06—COMPUTING; CALCULATING; COUNTING
- G06F—ELECTRICAL DIGITAL DATA PROCESSING
- G06F1/00—Details of data-processing equipment not covered by groups G06F3/00 - G06F13/00, e.g. cooling, packaging or power supply specially adapted for computer application
- G06F1/16—Constructional details or arrangements
- G06F1/20—Cooling means
-
- G—PHYSICS
- G06—COMPUTING; CALCULATING; COUNTING
- G06F—ELECTRICAL DIGITAL DATA PROCESSING
- G06F1/00—Details of data-processing equipment not covered by groups G06F3/00 - G06F13/00, e.g. cooling, packaging or power supply specially adapted for computer application
- G06F1/26—Power supply means, e.g. regulation thereof
- G06F1/32—Means for saving power
- G06F1/3203—Power Management, i.e. event-based initiation of power-saving mode
-
- H—ELECTRICITY
- H05—ELECTRIC TECHNIQUES NOT OTHERWISE PROVIDED FOR
- H05K—PRINTED CIRCUITS; CASINGS OR CONSTRUCTIONAL DETAILS OF ELECTRIC APPARATUS; MANUFACTURE OF ASSEMBLAGES OF ELECTRICAL COMPONENTS
- H05K7/00—Constructional details common to different types of electric apparatus
- H05K7/20—Modifications to facilitate cooling, ventilating, or heating
- H05K7/20709—Modifications to facilitate cooling, ventilating, or heating for server racks or cabinets; for data centers, e.g. 19-inch computer racks
- H05K7/20836—Thermal management, e.g. server temperature control
-
- G—PHYSICS
- G06—COMPUTING; CALCULATING; COUNTING
- G06F—ELECTRICAL DIGITAL DATA PROCESSING
- G06F1/00—Details of data-processing equipment not covered by groups G06F3/00 - G06F13/00, e.g. cooling, packaging or power supply specially adapted for computer application
- G06F1/16—Constructional details or arrangements
- G06F1/18—Packaging or power distribution
-
- H—ELECTRICITY
- H05—ELECTRIC TECHNIQUES NOT OTHERWISE PROVIDED FOR
- H05K—PRINTED CIRCUITS; CASINGS OR CONSTRUCTIONAL DETAILS OF ELECTRIC APPARATUS; MANUFACTURE OF ASSEMBLAGES OF ELECTRICAL COMPONENTS
- H05K7/00—Constructional details common to different types of electric apparatus
- H05K7/14—Mounting supporting structure in casing or on frame or rack
- H05K7/1485—Servers; Data center rooms, e.g. 19-inch computer racks
-
- G—PHYSICS
- G06—COMPUTING; CALCULATING; COUNTING
- G06F—ELECTRICAL DIGITAL DATA PROCESSING
- G06F11/00—Error detection; Error correction; Monitoring
- G06F11/30—Monitoring
- G06F11/3065—Monitoring arrangements determined by the means or processing involved in reporting the monitored data
Similar Documents
| Publication | Publication Date | Title |
|---|---|---|
| US10558768B1 (en) | Computer and data center load determination | |
| Fang et al. | Thermal-aware energy management of an HPC data center via two-time-scale control | |
| Fan et al. | Power provisioning for a warehouse-sized computer | |
| Bose et al. | Energy-efficient approach to lower the carbon emissions of data centers | |
| US10956841B2 (en) | Calculating power usage effectiveness in data centers | |
| Li et al. | Coordinating liquid and free air cooling with workload allocation for data center power minimization | |
| Ibrahim et al. | Thermal mass characterization of a server at different fan speeds | |
| Marwah et al. | Data analysis, visualization and knowledge discovery in sustainable data centers | |
| Reddy et al. | Best practices for sustainable datacenters | |
| Isaev et al. | Data center efficiency model: a new approach and the role of artificial intelligence | |
| Kumar et al. | Power usage efficiency (PUE) optimization with counterpointing machine learning techniques for data center temperatures | |
| Heydari et al. | Power usage effectiveness analysis of a high-density air-liquid hybrid cooled data center | |
| Ahmed et al. | Electrical energy consumption model of internal components in data centers | |
| Debusschere et al. | Data center energy consumption simulator from the servers to their cooling system | |
| Chisca et al. | On energy-and cooling-aware data centre workload management | |
| Seyedkazemi Ardebili et al. | Thermal characterization of a tier0 datacenter room in normal and thermal emergency conditions | |
| Rubenstein et al. | Hybrid cooled data center using above ambient liquid cooling | |
| Gil et al. | Optimization of energy consumption in HPC centers: Energy Efficiency Project of Castile and Leon Supercomputing Center-FCSCL | |
| Chen et al. | Optimization of electricity and server maintenance costs in hybrid cooling data centers | |
| McCumber et al. | Tooling to improve data center efficiency | |
| Huang et al. | Electric Power-grid Friendly Characteristic Data Center Energy Consumption Optimization Method | |
| Ardebili et al. | Rule-based thermal anomaly detection for tier-0 HPC systems | |
| Schödwell et al. | Towards a holistic multi-level green performance indicator framework (GPIF) to improve the Energy Efficiency of data center operation-A resource usage-based approach | |
| Choorat et al. | Design of Cooling System of Tier 3 Standard for Rack Enclosure in the Containerized Data Centers | |
| Molloy et al. | Improving data-center efficiency for a Smarter Planet |