Hsu, 2007 - Google Patents

Performance study on newly developed impellers for a left ventricular assist device

Hsu, 2007

Document ID
11613363979372582399
Author
Hsu C
Publication year
Publication venue
The International Journal of Artificial Organs

External Links

Snippet

Our research develops a performance study on newly developed impellers for a left ventricular assist device. In order to analyze the hemodynamic characteristics of blood flow through the ventricular assist device, the CFX-TASCflow software is adopted to investigate …
Continue reading at journals.sagepub.com (other versions)

Similar Documents

Publication Publication Date Title
Untaroiu et al. Numerical and experimental analysis of an axial flow left ventricular assist device: the influence of the diffuser on overall pump performance
King et al. Three-dimensional study of the effect of two leaflet opening angles on the time-dependent flow through a bileaflet mechanical heart valve
Song et al. Design and transient computational fluid dynamics study of a continuous axial flow ventricular assist device
Telyshev et al. The effect of rotor geometry on the H− Q curves of the Sputnik implantable pediatric rotary blood pump
Torner et al. Large-eddy and unsteady Reynolds-averaged Navier-Stokes simulations of an axial flow pump for cardiac support
Wang et al. Shear stress and hemolysis analysis of blood pump under constant and pulsation speed based on a multiscale coupling model
Ray et al. Numerical assessment of hemodynamic perspectives of a left ventricular assist device and subsequent proposal for improvisation
Chan et al. A computational study of the effects of inlet guide vanes on the performance of a centrifugal blood pump
Msº et al. Prediction of hemolysis in rotary blood pumps with computational fluid dynamics analysis
Hsu Performance study on newly developed impellers for a left ventricular assist device
Yu Flow design optimization of blood pumps considering hemolysis
Korakianitis et al. Optimization of axial pump characteristic dimensions and induced hemolysis for mechanical circulatory support devices
Li et al. Effect of V‐Shaped Groove Microstructure on Blood Flow Resistance in Bionic Artificial Blood Vessels
Chan et al. Numerical investigations of a centrifugal blood pump
Behr et al. Performance analysis of ventricular assist devices using finite element flow simulation
Hsu Flow study on a newly developed impeller for a left ventricular assist device
Malota et al. The Application of Bileaflet Mechanical Heart Valves in the P olish V entricular A ssist D evice: Physical and Numerical Study and First Clinical Usage
Mondee et al. The effect of shear stress on the impeller design of centrifugal blood PUMP
Hsu Blood flow analysis of polyurethane heart valves at peak systole
Yildizeli et al. Effect of the design modifications on the hemocompatibility and hydrodynamic performance of FDA-approved blood pump at various operating conditions
Lai et al. An Approach to automatically optimize the Hydraulic performance of Blade System for Hydraulic Machines using Multi-objective Genetic Algorithm
Yang et al. Structural design and numerical simulation of an implantable axial blood pump
Antony et al. Design, analysis and validation axial ventricular assist device
Cheng et al. Simulation analysis of centrifugal blood pump with elbow based on Fluent
Bleiziffer Development of an inverse design method for propellers with application on left ventricular devices