Lee et al., 2010 - Google Patents

A tunable biquad switched-capacitor amplifier-filter for neural recording

Lee et al., 2010

Document ID
15167863311871258504
Author
Lee J
Johnson M
Kipke D
Publication year
Publication venue
IEEE transactions on biomedical circuits and systems

External Links

Snippet

With the emerging interest in local field potentials (LFPs) as input signals for brain-machine interfaces, there is a need for integrated circuits capable of amplifying spikes and LFPs. A two-stage complementary metal-oxide semiconductor (CMOS) amplifier-filter has been …
Continue reading at ieeexplore.ieee.org (other versions)

Classifications

    • HELECTRICITY
    • H03BASIC ELECTRONIC CIRCUITRY
    • H03HIMPEDANCE NETWORKS, e.g. RESONANT CIRCUITS; RESONATORS
    • H03H11/00Networks using active elements
    • H03H11/02Multiple-port networks
    • H03H11/04Frequency selective two-port networks
    • H03H11/12Frequency selective two-port networks using amplifiers with feedback
    • H03H11/1291Current or voltage controlled filters
    • AHUMAN NECESSITIES
    • A61MEDICAL OR VETERINARY SCIENCE; HYGIENE
    • A61BDIAGNOSIS; SURGERY; IDENTIFICATION
    • A61B5/00Detecting, measuring or recording for diagnostic purposes; Identification of persons
    • A61B5/04Detecting, measuring or recording bioelectric signals of the body of parts thereof
    • A61B5/0476Electroencephalography
    • HELECTRICITY
    • H03BASIC ELECTRONIC CIRCUITRY
    • H03FAMPLIFIERS
    • H03F3/00Amplifiers with only discharge tubes or only semiconductor devices as amplifying elements
    • H03F3/45Differential amplifiers
    • H03F3/45071Differential amplifiers with semiconductor devices only
    • H03F3/45076Differential amplifiers with semiconductor devices only characterised by the way of implementation of the active amplifying circuit in the differential amplifier
    • AHUMAN NECESSITIES
    • A61MEDICAL OR VETERINARY SCIENCE; HYGIENE
    • A61BDIAGNOSIS; SURGERY; IDENTIFICATION
    • A61B5/00Detecting, measuring or recording for diagnostic purposes; Identification of persons
    • A61B5/05Detecting, measuring or recording for diagnosis by means of electric currents or magnetic fields; Measuring using microwaves or radiowaves
    • A61B5/053Measuring electrical impedance or conductance of a portion of the body
    • A61B5/0531Measuring skin impedance
    • AHUMAN NECESSITIES
    • A61MEDICAL OR VETERINARY SCIENCE; HYGIENE
    • A61BDIAGNOSIS; SURGERY; IDENTIFICATION
    • A61B5/00Detecting, measuring or recording for diagnostic purposes; Identification of persons
    • A61B5/04Detecting, measuring or recording bioelectric signals of the body of parts thereof
    • A61B5/04001Detecting, measuring or recording bioelectric signals of the body of parts thereof adapted to neuroelectric signals, e.g. nerve impulses
    • HELECTRICITY
    • H03BASIC ELECTRONIC CIRCUITRY
    • H03FAMPLIFIERS
    • H03F2203/00Indexing scheme relating to amplifiers with only discharge tubes or only semiconductor devices as amplifying elements covered by H03F3/00
    • H03F2203/45Indexing scheme relating to differential amplifiers
    • H03F2203/45138Two or more differential amplifiers in IC-block form are combined, e.g. measuring amplifiers
    • AHUMAN NECESSITIES
    • A61MEDICAL OR VETERINARY SCIENCE; HYGIENE
    • A61BDIAGNOSIS; SURGERY; IDENTIFICATION
    • A61B5/00Detecting, measuring or recording for diagnostic purposes; Identification of persons
    • A61B5/04Detecting, measuring or recording bioelectric signals of the body of parts thereof
    • A61B5/0488Electromyography
    • AHUMAN NECESSITIES
    • A61MEDICAL OR VETERINARY SCIENCE; HYGIENE
    • A61BDIAGNOSIS; SURGERY; IDENTIFICATION
    • A61B5/00Detecting, measuring or recording for diagnostic purposes; Identification of persons
    • A61B5/72Signal processing specially adapted for physiological signals or for diagnostic purposes
    • A61B5/7235Details of waveform analysis
    • HELECTRICITY
    • H03BASIC ELECTRONIC CIRCUITRY
    • H03FAMPLIFIERS
    • H03F2203/00Indexing scheme relating to amplifiers with only discharge tubes or only semiconductor devices as amplifying elements covered by H03F3/00
    • H03F2203/45Indexing scheme relating to differential amplifiers
    • H03F2203/45296Indexing scheme relating to differential amplifiers the AAC comprising one or more discrete capacitive elements, e.g. a transistor coupled as capacitor

Similar Documents

Publication Publication Date Title
Wu et al. A 16-channel CMOS chopper-stabilized analog front-end ECoG acquisition circuit for a closed-loop epileptic seizure control system
Qian et al. A micropower low-noise neural recording front-end circuit for epileptic seizure detection
Yazicioglu et al. A 200 μW eight-channel EEG acquisition ASIC for ambulatory EEG systems
Gosselin et al. A low-power integrated bioamplifier with active low-frequency suppression
CN103687536B (en) neuronal recording system
Denison et al. A 2.2/spl mu/w 94nv//spl radic/hz, chopper-stabilized instrumentation amplifier for eeg detection in chronic implants
Rieger Variable-gain, low-noise amplification for sampling front ends
Lee et al. A tunable biquad switched-capacitor amplifier-filter for neural recording
Teng et al. Programmable ExG biopotential front-end IC for wearable applications
Robinet et al. A Low-Power 0.7$\mu {\rm V_ {rms}} $32-Channel Mixed-Signal Circuit for ECoG Recordings
KR101832734B1 (en) Improved bio-potential measurement system
Wu et al. An energy-efficient small-area configurable analog front-end interface for diverse biosignals recording
Shiue et al. A bandwidth-tunable bioamplifier with voltage-controlled symmetric pseudo-resistors
Xu et al. A 1-V 450-nW fully integrated biomedical sensor interface system
AbuShawish et al. CMOS bio-medical amplifier based on tera-ohm pseudo-resistor for bio-detection system
Lim et al. A fully integrated electroencephalogram (EEG) analog front-end IC with capacitive input impedance boosting loop
Kárász et al. Tunable low noise amplifier implementation with low distortion pseudo-resistance for in vivo brain activity measurement
Chebli et al. Low noise and high CMRR front-end amplifier dedicated to portable EEG acquisition system
Li et al. A LFP/AP Mode Reconfigurable Analog Front-End Combining an Electrical EEEG-iEEG Model for the Closed-Loop VNS
Wang et al. A 140-dB CMRR low-noise instrumentation amplifier for neural signal sensing
Dwivedi et al. Local field potential measurement with low-power area-efficient neural recording amplifier
Yang et al. A multi-parameter bio-electric ASIC sensor with integrated 2-wire data transmission protocol for wearable healthcare system
Kassanos et al. Ultra-low power application-specific integrated circuits for sensing
Zhang et al. Design of ECG front end amplifier based on CMOS OTA
Sharma Design topologies for low-frequency and low-noise neural signal processing