Open side car heat exchanger that removes entire server heat load without any added fan power

Schmidt et al., 2010

Document ID
15845709087091977066
Author
Schmidt R
Iyengar M
Porter D
Weber G
Graybill D
Steffes J
Publication year
Publication venue
2010 12th IEEE Intersociety Conference on Thermal and Thermomechanical Phenomena in Electronic Systems

External Links

Snippet

The heat dissipated by electronic equipment continues to increase at a alarming rate. This has occurred for products covering a wide range of applications. Manufacturers of this equipment require that the equipment be maintained within an environmental envelope in …
Continue reading at ieeexplore.ieee.org (other versions)

Classifications

    • HELECTRICITY
    • H05ELECTRIC TECHNIQUES NOT OTHERWISE PROVIDED FOR
    • H05KPRINTED CIRCUITS; CASINGS OR CONSTRUCTIONAL DETAILS OF ELECTRIC APPARATUS; MANUFACTURE OF ASSEMBLAGES OF ELECTRICAL COMPONENTS
    • H05K7/00Constructional details common to different types of electric apparatus
    • H05K7/20Modifications to facilitate cooling, ventilating, or heating
    • H05K7/20709Modifications to facilitate cooling, ventilating, or heating for server racks or cabinets; for data centers, e.g. 19-inch computer racks
    • H05K7/20718Forced ventilation of a gaseous coolant
    • H05K7/20745Forced ventilation of a gaseous coolant within rooms for removing heat from cabinets, e.g. by air conditioning device
    • HELECTRICITY
    • H05ELECTRIC TECHNIQUES NOT OTHERWISE PROVIDED FOR
    • H05KPRINTED CIRCUITS; CASINGS OR CONSTRUCTIONAL DETAILS OF ELECTRIC APPARATUS; MANUFACTURE OF ASSEMBLAGES OF ELECTRICAL COMPONENTS
    • H05K7/00Constructional details common to different types of electric apparatus
    • H05K7/20Modifications to facilitate cooling, ventilating, or heating
    • H05K7/20009Modifications to facilitate cooling, ventilating, or heating using a gaseous coolant in electronic enclosures
    • H05K7/20136Forced ventilation, e.g. by fans
    • H05K7/20172Fan mounting or fan specifications
    • HELECTRICITY
    • H05ELECTRIC TECHNIQUES NOT OTHERWISE PROVIDED FOR
    • H05KPRINTED CIRCUITS; CASINGS OR CONSTRUCTIONAL DETAILS OF ELECTRIC APPARATUS; MANUFACTURE OF ASSEMBLAGES OF ELECTRICAL COMPONENTS
    • H05K7/00Constructional details common to different types of electric apparatus
    • H05K7/20Modifications to facilitate cooling, ventilating, or heating
    • H05K7/20709Modifications to facilitate cooling, ventilating, or heating for server racks or cabinets; for data centers, e.g. 19-inch computer racks
    • H05K7/20763Liquid cooling without phase change
    • GPHYSICS
    • G06COMPUTING; CALCULATING; COUNTING
    • G06FELECTRICAL DIGITAL DATA PROCESSING
    • G06F1/00Details of data-processing equipment not covered by groups G06F3/00 - G06F13/00, e.g. cooling, packaging or power supply specially adapted for computer application
    • G06F1/16Constructional details or arrangements
    • G06F1/20Cooling means
    • HELECTRICITY
    • H05ELECTRIC TECHNIQUES NOT OTHERWISE PROVIDED FOR
    • H05KPRINTED CIRCUITS; CASINGS OR CONSTRUCTIONAL DETAILS OF ELECTRIC APPARATUS; MANUFACTURE OF ASSEMBLAGES OF ELECTRICAL COMPONENTS
    • H05K7/00Constructional details common to different types of electric apparatus
    • H05K7/20Modifications to facilitate cooling, ventilating, or heating
    • H05K7/20536Modifications to facilitate cooling, ventilating, or heating for racks or cabinets of standardized dimensions, e.g. 19-inch electronic racks
    • H05K7/20554Forced ventilation of a gaseous coolant
    • H05K7/20572Forced ventilation of a gaseous coolant within cabinets for removing heat from sub-racks, e.g. plenum
    • H05K7/20581Cabinets including a drawer for fans
    • HELECTRICITY
    • H05ELECTRIC TECHNIQUES NOT OTHERWISE PROVIDED FOR
    • H05KPRINTED CIRCUITS; CASINGS OR CONSTRUCTIONAL DETAILS OF ELECTRIC APPARATUS; MANUFACTURE OF ASSEMBLAGES OF ELECTRICAL COMPONENTS
    • H05K7/00Constructional details common to different types of electric apparatus
    • H05K7/14Mounting supporting structure in casing or on frame or rack
    • H05K7/1485Servers; Data center rooms, e.g. 19-inch computer racks

Similar Documents

Publication Publication Date Title
Schmidt et al. Maintaining datacom rack inlet air temperatures with water cooled heat exchanger
US7667965B2 (en) Acoustically absorptive anti-recirculation panel for one or more electronics racks of a data center
Shrivastava et al. Comparative analysis of different data center airflow management configurations
US7286351B2 (en) Apparatus and method for facilitating cooling of an electronics rack employing a closed loop heat exchange system
US7646603B2 (en) Noise-reducing attachment apparatus for heat exchanger door of an electronics rack of a data center
US7971446B2 (en) Computing environments
JP4922943B2 (en) Electronic component housing cooling system and method
JP6433583B2 (en) Modular data center column infrastructure
US6704196B1 (en) Flow-through cooling in-the-round system
US8033122B2 (en) Dehumidifier apparatus and method
US7486512B2 (en) Apparatus for facilitating cooling of an electronics rack by mixing cooler air flow with re-circulating air flow in a re-circulation region
US20090086432A1 (en) Docking station with closed loop airlfow path for facilitating cooling of an electronics rack
US20080291626A1 (en) Method and apparatus for cooling electronic equipment
US20150334878A1 (en) Cooling unit and method
CN103037665B (en) A kind of electronic device cooling system with radiator cooler
GB2497191A (en) Direct facility coolant cooling of a rack-mounted heat exchanger
Schmidt et al. Open side car heat exchanger that removes entire server heat load without any added fan power
US20120100795A1 (en) Air-conditioning system
Iyengar et al. Thermal characterization of non-raised floor air cooled data centers using numerical modeling
Schmidt et al. Server rack rear door heat exchanger and the new ASHRAE recommended environmental guidelines
Nemati et al. Experimental failure analysis of a rear door heat exchanger with localized containment
Zhou et al. Enhancing rack servers air cooling capability with extra system inlet airflow through air ducts between racks
Srinarayana et al. A comparative study of raised-floor and hard-floor configurations in an air-cooled data centre
Bhopte et al. Numerical modeling of data center clusters: Impact of model complexity
Hamann et al. The impact of air flow leakage on server inlet air temperature in a raised floor data center