Wang et al., 2019 - Google Patents
A fast, linear Boltzmann transport equation solver for computed tomography dose calculation (Acuros CTD)Wang et al., 2019
View PDF- Document ID
- 15927041266425926164
- Author
- Wang A
- Maslowski A
- Wareing T
- Star‐Lack J
- Schmidt T
- Publication year
- Publication venue
- Medical physics
External Links
Snippet
Purpose To improve dose reporting of CT scans, patient‐specific organ doses are highly desired. However, estimating the dose distribution in a fast and accurate manner remains challenging, despite advances in Monte Carlo methods. In this work, we present an …
- 238000002591 computed tomography 0 title abstract description 10
Classifications
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61N—ELECTROTHERAPY; MAGNETOTHERAPY; RADIATION THERAPY; ULTRASOUND THERAPY
- A61N5/00—Radiation therapy
- A61N5/10—X-ray therapy; Gamma-ray therapy; Particle-irradiation therapy
- A61N5/103—Treatment planning systems
- A61N5/1031—Treatment planning systems using a specific method of dose optimization
-
- G—PHYSICS
- G06—COMPUTING; CALCULATING; COUNTING
- G06T—IMAGE DATA PROCESSING OR GENERATION, IN GENERAL
- G06T11/00—2D [Two Dimensional] image generation
- G06T11/003—Reconstruction from projections, e.g. tomography
- G06T11/005—Specific pre-processing for tomographic reconstruction, e.g. calibration, source positioning, rebinning, scatter correction, retrospective gating
-
- G—PHYSICS
- G06—COMPUTING; CALCULATING; COUNTING
- G06T—IMAGE DATA PROCESSING OR GENERATION, IN GENERAL
- G06T2211/00—Image generation
- G06T2211/40—Computed tomography
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B6/00—Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
- A61B6/02—Devices for diagnosis sequentially in different planes; Stereoscopic radiation diagnosis
- A61B6/03—Computerised tomographs
- A61B6/032—Transmission computed tomography [CT]
Similar Documents
| Publication | Publication Date | Title |
|---|---|---|
| Maslowski et al. | Acuros CTS: A fast, linear Boltzmann transport equation solver for computed tomography scatter–Part I: Core algorithms and validation | |
| Wang et al. | A fast, linear Boltzmann transport equation solver for computed tomography dose calculation (Acuros CTD) | |
| Schulte et al. | Density resolution of proton computed tomography | |
| Ojala et al. | The accuracy of Acuros XB algorithm for radiation beams traversing a metallic hip implant—comparison with measurements and Monte Carlo calculations | |
| Park et al. | Proton dose calculation on scatter‐corrected CBCT image: feasibility study for adaptive proton therapy | |
| Tzedakis et al. | The effect of overscanning on patient effective dose from multidetector helical computed tomography examinations | |
| Lee et al. | Organ doses for reference adult male and female undergoing computed tomography estimated by Monte Carlo simulations | |
| Zhu et al. | Scatter correction for cone‐beam CT in radiation therapy | |
| Li et al. | Patient‐specific radiation dose and cancer risk estimation in CT: part I. Development and validation of a Monte Carlo program | |
| Grimes et al. | Comparison of internal dose estimates obtained using organ‐level, voxel S value, and Monte Carlo techniques | |
| Botta et al. | Use of the FLUKA Monte Carlo code for 3D patient-specific dosimetry on PET-CT and SPECT-CT images | |
| Wu et al. | Metal artifact correction for x‐ray computed tomography using kV and selective MV imaging | |
| Bootsma et al. | The effects of compensator and imaging geometry on the distribution of x‐ray scatter in CBCT | |
| Popple et al. | Comprehensive evaluation of a commercial macro Monte Carlo electron dose calculation implementation using a standard verification data set | |
| Penfold et al. | A more accurate reconstruction system matrix for quantitative proton computed tomography | |
| Lalonde et al. | A Bayesian approach to solve proton stopping powers from noisy multi‐energy CT data | |
| EP3077940B1 (en) | Method and system for dose calculation based on continuous material indexing | |
| Rong et al. | Optimization of energy window for 90Y bremsstrahlung SPECT imaging for detection tasks using the ideal observer with model‐mismatch | |
| Hansen et al. | Improved proton computed tomography by dual modality image reconstruction | |
| Reinhart et al. | A kernel-based dose calculation algorithm for kV photon beams with explicit handling of energy and material dependencies | |
| Chen et al. | Optimization of the geometry and speed of a moving blocker system for cone‐beam computed tomography scatter correction | |
| Principi et al. | Deterministic linear Boltzmann transport equation solver for patient‐specific CT dose estimation: Comparison against a Monte Carlo benchmark for realistic scanner configurations and patient models | |
| Malusek et al. | A model‐based iterative reconstruction algorithm DIRA using patient‐specific tissue classification via DECT for improved quantitative CT in dose planning | |
| Brady et al. | Ultralow dose computed tomography attenuation correction for pediatric PET CT using adaptive statistical iterative reconstruction | |
| Liu et al. | Impact of bowtie filter and detector collimation on multislice CT scatter profiles: a simulation study |