Paulus et al., 2012 - Google Patents
Simultaneous PET/MR imaging: MR‐based attenuation correction of local radiofrequency surface coilsPaulus et al., 2012
- Document ID
- 16174498970793006795
- Author
- Paulus D
- Braun H
- Aklan B
- Quick H
- Publication year
- Publication venue
- Medical physics
External Links
Snippet
Purpose: In simultaneous positron emission tomography/magnetic resonance (PET/MR) imaging, local receiver surface radiofrequency (RF) coils are positioned in the field‐of‐view (FOV) of the PET detector during PET/MR data acquisition and potentially attenuate the PET …
- 238000003384 imaging method 0 title abstract description 38
Classifications
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01R—MEASURING ELECTRIC VARIABLES; MEASURING MAGNETIC VARIABLES
- G01R33/00—Arrangements or instruments for measuring magnetic variables
- G01R33/20—Arrangements or instruments for measuring magnetic variables involving magnetic resonance
- G01R33/44—Arrangements or instruments for measuring magnetic variables involving magnetic resonance using nuclear magnetic resonance [NMR]
- G01R33/48—NMR imaging systems
- G01R33/54—Signal processing systems, e.g. using pulse sequences, Generation or control of pulse sequences ; Operator Console
- G01R33/56—Image enhancement or correction, e.g. subtraction or averaging techniques, e.g. improvement of signal-to-noise ratio and resolution
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01R—MEASURING ELECTRIC VARIABLES; MEASURING MAGNETIC VARIABLES
- G01R33/00—Arrangements or instruments for measuring magnetic variables
- G01R33/20—Arrangements or instruments for measuring magnetic variables involving magnetic resonance
- G01R33/44—Arrangements or instruments for measuring magnetic variables involving magnetic resonance using nuclear magnetic resonance [NMR]
- G01R33/48—NMR imaging systems
- G01R33/4808—Multimodal MR, e.g. MR combined with positron emission tomography [PET], MR combined with ultrasound or MR combined with computed tomography [CT]
- G01R33/481—MR combined with positron emission tomography [PET] or single photon emission computed tomography [SPECT]
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01R—MEASURING ELECTRIC VARIABLES; MEASURING MAGNETIC VARIABLES
- G01R33/00—Arrangements or instruments for measuring magnetic variables
- G01R33/20—Arrangements or instruments for measuring magnetic variables involving magnetic resonance
- G01R33/28—Details of apparatus provided for in groups G01R33/44 - G01R33/64
- G01R33/38—Systems for generation, homogenisation or stabilisation of the main or gradient magnetic field
- G01R33/381—Systems for generation, homogenisation or stabilisation of the main or gradient magnetic field using electromagnets
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01R—MEASURING ELECTRIC VARIABLES; MEASURING MAGNETIC VARIABLES
- G01R33/00—Arrangements or instruments for measuring magnetic variables
- G01R33/20—Arrangements or instruments for measuring magnetic variables involving magnetic resonance
- G01R33/28—Details of apparatus provided for in groups G01R33/44 - G01R33/64
- G01R33/32—Excitation or detection systems, e.g. using radio frequency signals
- G01R33/34—Constructional details, e.g. resonators, specially adapted to MR
- G01R33/341—Constructional details, e.g. resonators, specially adapted to MR comprising surface coils
-
- G—PHYSICS
- G01—MEASURING; TESTING
- G01T—MEASUREMENT OF NUCLEAR OR X-RADIATION
- G01T1/00—Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
- G01T1/29—Measurement performed on radiation beams, e.g. position or section of the beam; Measurement of spatial distribution of radiation
- G01T1/2914—Measurement of spatial distribution of radiation
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B5/00—Detecting, measuring or recording for diagnostic purposes; Identification of persons
- A61B5/05—Detecting, measuring or recording for diagnosis by means of electric currents or magnetic fields; Measuring using microwaves or radiowaves
- A61B5/055—Detecting, measuring or recording for diagnosis by means of electric currents or magnetic fields; Measuring using microwaves or radiowaves involving electronic or nuclear magnetic resonance, e.g. magnetic resonance imaging
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B6/00—Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
- A61B6/02—Devices for diagnosis sequentially in different planes; Stereoscopic radiation diagnosis
- A61B6/03—Computerised tomographs
- A61B6/032—Transmission computed tomography [CT]
-
- A—HUMAN NECESSITIES
- A61—MEDICAL OR VETERINARY SCIENCE; HYGIENE
- A61B—DIAGNOSIS; SURGERY; IDENTIFICATION
- A61B6/00—Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
- A61B6/02—Devices for diagnosis sequentially in different planes; Stereoscopic radiation diagnosis
- A61B6/03—Computerised tomographs
- A61B6/037—Emission tomography
-
- G—PHYSICS
- G06—COMPUTING; CALCULATING; COUNTING
- G06T—IMAGE DATA PROCESSING OR GENERATION, IN GENERAL
- G06T2207/00—Indexing scheme for image analysis or image enhancement
- G06T2207/10—Image acquisition modality
- G06T2207/10072—Tomographic images
- G06T2207/10084—Hybrid tomography; Concurrent acquisition with multiple different tomographic modalities
Similar Documents
| Publication | Publication Date | Title |
|---|---|---|
| Paulus et al. | Simultaneous PET/MR imaging: MR‐based attenuation correction of local radiofrequency surface coils | |
| Paulus et al. | Towards integration of PET/MR hybrid imaging into radiation therapy treatment planning | |
| Kolb et al. | Technical performance evaluation of a human brain PET/MRI system | |
| Tellmann et al. | The effect of MR surface coils on PET quantification in whole‐body PET/MR: Results from a pseudo‐PET/MR phantom study | |
| Quick | Integrated PET/Mr | |
| Aklan et al. | Toward simultaneous PET/MR breast imaging: systematic evaluation and integration of a radiofrequency breast coil | |
| Heusch et al. | Standardized uptake values for [18F] FDG in normal organ tissues: comparison of whole-body PET/CT and PET/MRI | |
| Boellaard et al. | Quality control for quantitative multicenter whole‐body PET/MR studies: a NEMA image quality phantom study with three current PET/MR systems | |
| Catana | Principles of simultaneous PET/MR imaging | |
| Sander et al. | A 31‐channel MR brain array coil compatible with positron emission tomography | |
| Grant et al. | Simultaneous PET/MR imaging with a radio frequency‐penetrable PET insert | |
| Paulus et al. | Hybrid positron emission tomography/magnetic resonance imaging: challenges, methods, and state of the art of hardware component attenuation correction | |
| CN104736062B (en) | MR receive coil localization and MR-based attenuation correction | |
| Appenzeller et al. | PET/CT versus body coil PET/MRI: how low can you go? | |
| Oehmigen et al. | Integrated PET/MR breast cancer imaging: Attenuation correction and implementation of a 16‐channel RF coil | |
| WO2015022660A2 (en) | System for simultaneous pet/mr imaging | |
| Boss et al. | Diffusion tensor imaging in a human PET/MR hybrid system | |
| Rausch et al. | Standard MRI-based attenuation correction for PET/MRI phantoms: a novel concept using MRI-visible polymer | |
| CN104068858B (en) | The method and apparatus of the magnetic resonance-positron emission device signal value of display combination | |
| Nardini et al. | Tuning the optimal diffusion-weighted MRI parameters on a 0.35-T MR-Linac for clinical implementation: A phantom study | |
| Bindseil et al. | First image from a combined positron emission tomography and field‐cycled MRI system | |
| Oehmigen et al. | A dual‐tuned 13C/1H head coil for PET/MR hybrid neuroimaging: Development, attenuation correction, and first evaluation | |
| Zhang et al. | Prostate diffusion MRI with minimal echo time using eddy current nulled convex optimized diffusion encoding | |
| Farag et al. | Assessment of a novel 32-channel phased array for cardiovascular hybrid PET/MRI imaging: MRI performance | |
| Sasaki et al. | Does integrated shimming improve lesion detection in whole-body diffusion-weighted examinations of patients with breast cancer? |