[go: up one dir, main page]

Paulus et al., 2012 - Google Patents

Simultaneous PET/MR imaging: MR‐based attenuation correction of local radiofrequency surface coils

Paulus et al., 2012

Document ID
16174498970793006795
Author
Paulus D
Braun H
Aklan B
Quick H
Publication year
Publication venue
Medical physics

External Links

Snippet

Purpose: In simultaneous positron emission tomography/magnetic resonance (PET/MR) imaging, local receiver surface radiofrequency (RF) coils are positioned in the field‐of‐view (FOV) of the PET detector during PET/MR data acquisition and potentially attenuate the PET …
Continue reading at aapm.onlinelibrary.wiley.com (other versions)

Classifications

    • GPHYSICS
    • G01MEASURING; TESTING
    • G01RMEASURING ELECTRIC VARIABLES; MEASURING MAGNETIC VARIABLES
    • G01R33/00Arrangements or instruments for measuring magnetic variables
    • G01R33/20Arrangements or instruments for measuring magnetic variables involving magnetic resonance
    • G01R33/44Arrangements or instruments for measuring magnetic variables involving magnetic resonance using nuclear magnetic resonance [NMR]
    • G01R33/48NMR imaging systems
    • G01R33/54Signal processing systems, e.g. using pulse sequences, Generation or control of pulse sequences ; Operator Console
    • G01R33/56Image enhancement or correction, e.g. subtraction or averaging techniques, e.g. improvement of signal-to-noise ratio and resolution
    • GPHYSICS
    • G01MEASURING; TESTING
    • G01RMEASURING ELECTRIC VARIABLES; MEASURING MAGNETIC VARIABLES
    • G01R33/00Arrangements or instruments for measuring magnetic variables
    • G01R33/20Arrangements or instruments for measuring magnetic variables involving magnetic resonance
    • G01R33/44Arrangements or instruments for measuring magnetic variables involving magnetic resonance using nuclear magnetic resonance [NMR]
    • G01R33/48NMR imaging systems
    • G01R33/4808Multimodal MR, e.g. MR combined with positron emission tomography [PET], MR combined with ultrasound or MR combined with computed tomography [CT]
    • G01R33/481MR combined with positron emission tomography [PET] or single photon emission computed tomography [SPECT]
    • GPHYSICS
    • G01MEASURING; TESTING
    • G01RMEASURING ELECTRIC VARIABLES; MEASURING MAGNETIC VARIABLES
    • G01R33/00Arrangements or instruments for measuring magnetic variables
    • G01R33/20Arrangements or instruments for measuring magnetic variables involving magnetic resonance
    • G01R33/28Details of apparatus provided for in groups G01R33/44 - G01R33/64
    • G01R33/38Systems for generation, homogenisation or stabilisation of the main or gradient magnetic field
    • G01R33/381Systems for generation, homogenisation or stabilisation of the main or gradient magnetic field using electromagnets
    • GPHYSICS
    • G01MEASURING; TESTING
    • G01RMEASURING ELECTRIC VARIABLES; MEASURING MAGNETIC VARIABLES
    • G01R33/00Arrangements or instruments for measuring magnetic variables
    • G01R33/20Arrangements or instruments for measuring magnetic variables involving magnetic resonance
    • G01R33/28Details of apparatus provided for in groups G01R33/44 - G01R33/64
    • G01R33/32Excitation or detection systems, e.g. using radio frequency signals
    • G01R33/34Constructional details, e.g. resonators, specially adapted to MR
    • G01R33/341Constructional details, e.g. resonators, specially adapted to MR comprising surface coils
    • GPHYSICS
    • G01MEASURING; TESTING
    • G01TMEASUREMENT OF NUCLEAR OR X-RADIATION
    • G01T1/00Measuring X-radiation, gamma radiation, corpuscular radiation, or cosmic radiation
    • G01T1/29Measurement performed on radiation beams, e.g. position or section of the beam; Measurement of spatial distribution of radiation
    • G01T1/2914Measurement of spatial distribution of radiation
    • AHUMAN NECESSITIES
    • A61MEDICAL OR VETERINARY SCIENCE; HYGIENE
    • A61BDIAGNOSIS; SURGERY; IDENTIFICATION
    • A61B5/00Detecting, measuring or recording for diagnostic purposes; Identification of persons
    • A61B5/05Detecting, measuring or recording for diagnosis by means of electric currents or magnetic fields; Measuring using microwaves or radiowaves
    • A61B5/055Detecting, measuring or recording for diagnosis by means of electric currents or magnetic fields; Measuring using microwaves or radiowaves involving electronic or nuclear magnetic resonance, e.g. magnetic resonance imaging
    • AHUMAN NECESSITIES
    • A61MEDICAL OR VETERINARY SCIENCE; HYGIENE
    • A61BDIAGNOSIS; SURGERY; IDENTIFICATION
    • A61B6/00Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
    • A61B6/02Devices for diagnosis sequentially in different planes; Stereoscopic radiation diagnosis
    • A61B6/03Computerised tomographs
    • A61B6/032Transmission computed tomography [CT]
    • AHUMAN NECESSITIES
    • A61MEDICAL OR VETERINARY SCIENCE; HYGIENE
    • A61BDIAGNOSIS; SURGERY; IDENTIFICATION
    • A61B6/00Apparatus for radiation diagnosis, e.g. combined with radiation therapy equipment
    • A61B6/02Devices for diagnosis sequentially in different planes; Stereoscopic radiation diagnosis
    • A61B6/03Computerised tomographs
    • A61B6/037Emission tomography
    • GPHYSICS
    • G06COMPUTING; CALCULATING; COUNTING
    • G06TIMAGE DATA PROCESSING OR GENERATION, IN GENERAL
    • G06T2207/00Indexing scheme for image analysis or image enhancement
    • G06T2207/10Image acquisition modality
    • G06T2207/10072Tomographic images
    • G06T2207/10084Hybrid tomography; Concurrent acquisition with multiple different tomographic modalities

Similar Documents

Publication Publication Date Title
Paulus et al. Simultaneous PET/MR imaging: MR‐based attenuation correction of local radiofrequency surface coils
Paulus et al. Towards integration of PET/MR hybrid imaging into radiation therapy treatment planning
Kolb et al. Technical performance evaluation of a human brain PET/MRI system
Tellmann et al. The effect of MR surface coils on PET quantification in whole‐body PET/MR: Results from a pseudo‐PET/MR phantom study
Quick Integrated PET/Mr
Aklan et al. Toward simultaneous PET/MR breast imaging: systematic evaluation and integration of a radiofrequency breast coil
Heusch et al. Standardized uptake values for [18F] FDG in normal organ tissues: comparison of whole-body PET/CT and PET/MRI
Boellaard et al. Quality control for quantitative multicenter whole‐body PET/MR studies: a NEMA image quality phantom study with three current PET/MR systems
Catana Principles of simultaneous PET/MR imaging
Sander et al. A 31‐channel MR brain array coil compatible with positron emission tomography
Grant et al. Simultaneous PET/MR imaging with a radio frequency‐penetrable PET insert
Paulus et al. Hybrid positron emission tomography/magnetic resonance imaging: challenges, methods, and state of the art of hardware component attenuation correction
CN104736062B (en) MR receive coil localization and MR-based attenuation correction
Appenzeller et al. PET/CT versus body coil PET/MRI: how low can you go?
Oehmigen et al. Integrated PET/MR breast cancer imaging: Attenuation correction and implementation of a 16‐channel RF coil
WO2015022660A2 (en) System for simultaneous pet/mr imaging
Boss et al. Diffusion tensor imaging in a human PET/MR hybrid system
Rausch et al. Standard MRI-based attenuation correction for PET/MRI phantoms: a novel concept using MRI-visible polymer
CN104068858B (en) The method and apparatus of the magnetic resonance-positron emission device signal value of display combination
Nardini et al. Tuning the optimal diffusion-weighted MRI parameters on a 0.35-T MR-Linac for clinical implementation: A phantom study
Bindseil et al. First image from a combined positron emission tomography and field‐cycled MRI system
Oehmigen et al. A dual‐tuned 13C/1H head coil for PET/MR hybrid neuroimaging: Development, attenuation correction, and first evaluation
Zhang et al. Prostate diffusion MRI with minimal echo time using eddy current nulled convex optimized diffusion encoding
Farag et al. Assessment of a novel 32-channel phased array for cardiovascular hybrid PET/MRI imaging: MRI performance
Sasaki et al. Does integrated shimming improve lesion detection in whole-body diffusion-weighted examinations of patients with breast cancer?